Optical Sensors | Spectroscopy | Optical Flow Meters | Downhole Pressure & Temperature Sensors

Spectroscopy
Our spectrometers facilitate measurements in the ultra-violet, visible and near-infrared wavelengths - ranging from chemical composition and quantification to color measurement and radiometry.

We not only offer a comprehensive range of spectroscopy products, including spectrometers, light sources, software and accessories, but we can also design and manufacture custom solutions for OEM applications.

Applications include:
  • Visible spectrum/ color monitoring

  • UV, Visible, NIR (Near Infrared)

  • Biophotonics

  • Transmission

  • Laser / light source monitoring

  • Absorption

  • Fluorescence

  • Molar concentration

  • Optical inspection

  • Chemical analysis

  • Reflection

  • Scattering


Download datasheet.

Case Study.

Click headers to expand/collapse the different spectrometer models.

SPM - 001

Common Specifications
Wavelength Range (nm) 350-2500
Interface USB 2.0
Power Requirements 10-14 VDC, 300-1200 mA @12VDC
Weight (g) 1100 for SPM-001 (N-M) (g) 1400 for SPM-001 NIR 1700S / 2500W

1. Slit sizes of 10,25,50 and 100um are available
2. SMA or FC fiber input available on all models
3. Custom spectrometer wavelength ranges and slit sizes are available upon request.

SPM-001 M N NIR1700S NIR2500W
Spectral Range (nm) 740-860 680-920 900-1700 1250-2500
Resolution (center/outer)(nm) 0.12/0.18 0.24/0.30 3.5/5 5/8
Standard Slit (um) 10 10 25 25
Fiber Input FC FC SMA SMA
Detector Type CCD CCD InGaAs,single stage cooling InGaAs,single stage cooling
Pixels 3648 3648 512 512
A/D Converter (bits) 12 12 16 16
Exposure Time Range 10usec to 65sec 10usec to 65sec 10usec to 10sec 10usec to 10sec
Dimensions (mm) 192 x 89.5 x 52.6 192 x 89.5 x 52.6 236 x 89.5 x 52.6 236 x 89.5 x 52.6
Temperature Range (C°) -10C°to + 55C° -10C°to + 55C° -10C°to + 55C° -10C°to + 55C°


Download datasheet.

SPM - 002 Compact Spectrometer

Common Specifications
Wavelength Range (nm) 190-1700
Dimensions (mm) 101.5 x 90 x 54.3
Interface USB 2.0
Weight (g) 500
Fiber Input SMA
Power Requirments 10-14 VDC, 300mA @ 12VDC and / or USB Powered

1. Slit sizes of 10,25,50 and 100um are available
2. SMA or FC fiber input available on all models

SPM-002 A B C D E
Spectral Range (nm) 400-700 190-400 350-1000 200-850 200-1090
Resolution (center/outer) (nm)* 0.5/0.6 0.6/0.7 0.5/1.2 0.6/1.6 0.8/2
Standard Slit (um) 25 25 25 25 25
Detector Type CCD CCD CCD CCD CCD
Pixels 3648 3648 3648 3648 3648
A/D Converter (bits) 12 12 12 12 12
Exposure Time Range 10usec to 65 sec 10usec to 65 sec 10usec to 65 sec 10usec to 65 sec 10usec to 65 sec
Temperature Range (C°) -10 to 55 -10 to 55 -10 to 55 -10 to 55 -10 to 55


SPM-002 AH BH CH DH EH
Spectral Range (nm) 400-700 190-400 350-1000 200-850 200-1090
Resolution (center/outer) (nm)* 0.5/0.6 0.6/0.7 0.5/1.2 0.6/1.6 0.8/2
Standard Slit (um) 25 25 25 25 25
Detector Type CCD CCD CCD CCD CCD
Pixels 3648 3648 3648 3648 3648
A/D Converter (bits) 16 16 16 16 16
Exposure Time Range 10usec to 65 sec 10usec to 65 sec 10usec to 65 sec 10usec to 65 sec 10usec to 65 sec
Temperature Range (C°) -10 to 55 -10 to 55 -10 to 55 -10 to 55 -10 to 55

Model Specific Specifications: Back-thinned CCD and InGaAs Linear Array

SPM-002 BT DT ET
Spectral Range (nm) 190-400 200-850 200-1090
Resolution (center/outer) (nm)* 0.6/0.7 0.6/1.6 0.8/2
Standard Slit (um) 25 25 25
Detector Type Back-thinned CCD Back-thinned CCD Back-thinned CCD
Pixels 2048x14 2048x14 2048x14
A/D Converter (bits) 16 16 16
Exposure Time Range 2.2msec to 10 sec 2.2msec to 10 sec 2.2msec to 10 sec
Temperature Range (C°) -10 to 40 -10 to 40 -10 to 40


SPM-002 BT64 DT64 ET64 NIR1700
Spectral Range (nm) 190-400 200-850 200-1090 900-1700
Resolution (center/outer) (nm)* 0.6/0.7 0.6/1.6 0.8/2 3.5/5
Standard Slit (um) 25 25 25 25
Detector Type Back-thinned CCD Back-thinned CCD Back-thinned CCD InGaAs
Pixels 2048x14 2048x14 2048x14 512
A/D Converter (bits) 16 16 16 16
Exposure Time Range 3msec to 10 sec 3msec to 10 sec 3msec to 10 sec 10usec to 10 sec
Temperature Range (C°) -10 to 40 -10 to 40 -10 to 40 -10 to 40

* measured with 10 um slit for SPM-002-X/XH/XT64

Download datasheet.

SPM-002-X-Rad Spectroradiometer System

Common Specifications
Wavelength Range (nm) 220-1050
Dimensions (mm) 101.5 x 90 x 54.3
Interface USB 2.0
Weight (g) 2268
Fiber Input SMA
Power Requirments 10-14 VDC, 300mA @ 12VDC and / or USB Powered

1. Slit size of 100um

SPM-002-X-Rad Spectroradiometer System

SPM-002-X-Rad A-Rad B-Rad C-Rad D-Rad E-Rad
Spectral Range (nm) 400-700 190-400 350-1000 200-850 200-1090
Radiometric Range (nm) 400-700 220-400 350-1000 200-850 220-1050
Resolution (FWHM) (nm)
(center/outer specral range,
100um slit)
1.4/1.5 1.3/1.4 2.6/2.7 2.6/2.7 3.5/3.7
Detector Type CCD CCD CCD CCD CCD
Pixels 3648 3648 3648 3648 3648
A/D Converter (bits) 16 16 16 16 16
Exposure Time Range 10usec to 65 sec 10 usec to 65 sec 10 usec to 65 sec 10 usec to 65 sec 10 usec to 65 sec
Temperature Range (C°) 10 to 35 10 to 35 10 to 35 10 to 35 10 to 35


Download datasheet.

Light Sources


Light Source

Model Spectral Range (nm) Lifetime (MTBF, hrs) Fiber Connector Operating Temp. Range (C°) Power Supply Dimensions (mm) Weight (g)
SPL-2H
Tungsten-Halogen
350-2000 10000 SMA -10 to 60 12 VDC, 650mA 116x40x43 165
SPL-1DH Deuterium-Halogen 200-110 D2-1000;
Halogen2000
SMA 5 to 35 12 VDC, 650mA 118x81x47 385
SPL-HGAR Mercury-Argon 250-1000 3000 SMA 10 to 40 12 VDC, 650mA 145x62x23 135


Download datasheet.

Spectrometer Accessories

Spectroscopy Patch Cords and Sampling Accessories

Photos Reflectance Probes, Cuvette Holder, Breakout Board, etc

Item Description
SPA-COU Cuvette Holder, 4 way
SPA-RP-SMA-200-U Reflectance probe, 6 around 1, 200um core UV/Vis fibers, SMA connectors
   
SPA-RP-SMA-200-V Reflectance probe, 6 around 1, 200um core Vis/NIR fibers, SMA connectors
   
SPA-COL-UVI-SMA Light Collector, UV/Vis/IR, SMA
CWA-SMA-62-V-2 Fiber Optic Patch Cord - SMA 905 connector - 62.5 micrometer core - VIS/NIR - 2m
CWA-SMA-100-V-2 Fiber Optic Patch Cord - SMA 905 connector - 100 micrometer core - VIS/NIR - 2m
CWA-SMA-200-V-2 Fiber Optic Patch Cord - SMA 905 connector - 200 micrometer core - VIS/NIR - 2m
CWA-SMA-400-V-2 Fiber Optic Patch Cord - SMA 905 connector - 400 micrometer core - VIS/NIR - 2m
CWA-SMA-600-V-2 Fiber Optic Patch Cord - SMA 905 connector - 600 micrometer core - VIS/NIR - 2m
CWA-SMA-100-U-2 Fiber Optic Patch Cord - SMA 905 connector - 100 micrometer core - UV/VIS - 2m
CWA-SMA-200-U-2 Fiber Optic Patch Cord - SMA 905 connector - 200 micrometer core - UV/VIS - 2m
CWA-SMA-400-U-2 Fiber Optic Patch Cord - SMA 905 connector - 400micrometer core - UV/VIS - 2m
CWA-SMA-600-U-2 Fiber Optic Patch Cord - SMA 905 connector - 600 micrometer core - UV/VIS - 2m
   
SPA-COL-UVI-FC Light Collector, UV/Vis/IR, FC
SPA-WREF-1 White Reference Standard
SPA-PL-COUV-1 Plastic Cuvettes, 1cm path, 10pack
SPA-RP-HOLD-1 Reflectance probe holder
SPA-BREAKOUT-1 Breakout circuit board for spectrometer interface connector
   
CWA-FC-62-V-2 Fiber Optic Patch Cord - FC connector - 62.5 micrometer core - VIS/NIR - 2m
CWA-FC-100-V-2 Fiber Optic Patch Cord - FC connector - 100 micrometer core - VIS/NIR - 2m
CWA-FC-200-V-2 Fiber Optic Patch Cord - FC connector - 200 micrometer core - VIS/NIR - 2m
CWA-FC-400-V-2 Fiber Optic Patch Cord - FC connector - 400 micrometer core - VIS/NIR - 2m
CWA-FC-600-V-2 Fiber Optic Patch Cord - FC connector - 600 micrometer core - VIS/NIR - 2m
CWA-FC-100-U-2 Fiber Optic Patch Cord - FC connector - 100 micrometer core - UV/VIS - 2m
CWA-FC-200-U-2 Fiber Optic Patch Cord - FC connector - 200 micrometer core - UV/VIS - 2m
CWA-FC-400-U-2 Fiber Optic Patch Cord - FC connector - 400 micrometer core - UV/VIS - 2m
CWA-FC-600-U-2 Fiber Optic Patch Cord - FC connector - 600 micrometer core - UV/VIS - 2m
CWA-FC-SMF-V-2 Fiber Optic Patch Cord - FC connector - SMF 28 fiber - VIS/NIR - 2m


Download datasheet.

Stay Connected
Stay up to date with Photon Control!



Privacy Policy / Disclaimer